Double Beam UV Visible Spectrophotometer QTS-A42
Specifications:
Optical System Double Beam, Grating 1200 lines/mm
Wavelength Range 190-1100 nm
Spectral Bandwidth 2nm
Wavelength Accuracy ±0.1nm@656.1nm, ±0.3nm@all
Wavelength Repeatability <=0.1nm
Photometric Accuracy 0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A)
Photometric Repeatability ≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A)
Photometric Range 0-200%T, -0.3~3A, 0-9999C
Stray Light <=0.03%T@220nm, 360nm
Stability ±0.0005A/h@500nm
Baseline Flatness ±0.002A
Noise 0.0005A@500nm
Work Mode T, A, C, E
Scanning Speed Hi, Med, Low (Max. 3000nm/min)
Wavelength Setting Auto
Display 320*240 LCD
Light Source Deuterium & Tungsten lamp
Detector Imported Silicon Photodiode
Cuvette Holder 10mm manual 4-cell holder
Output USB, RS232
Power AC 110-220V 50-60Hz
Shipping Size 810*660*390mm
880*690*520mm Gross Weight 27kg
Standard Accessories 10mm glass cuvette x 4, 10mm quartz cuvette x 2, Power cord, User’s Manual ,PC Analysis software
Double Beam UV Visible Spectrophotometer QTS-A43
Specifications:
Optical System Double Beam, Grating 1200 lines/mm
Wavelength Range 190-1100 nm
Spectral Bandwidth 1nm
Wavelength Accuracy ±0.1nm@656.1nm, ±0.3nm@all
Wavelength Repeatability <=0.1nm
Photometric Accuracy 0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A)
Photometric Repeatability ≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A)
Photometric Range 0-200%T, -0.3~3A, 0-9999C
Stray Light <=0.03%T@220nm, 360nm
Stability ±0.0005A/h@500nm
Baseline Flatness ±0.001A
Noise 0.0005A@500nm
Work Mode T, A, C, E
Scanning Speed Hi, Med, Low (Max. 3000nm/min)
Wavelength Setting Auto
Display 320*240 LCD
Light Source Deuterium & Tungsten lamp
Detector Imported Silicon Photodiode
Cuvette Holder 10mm manual 4-cell holder
Output USB, RS232
Power AC 110-220V 50-60Hz
Shipping Size 810*660*390mm
880*690*520mm Gross Weight 27kg
Standard Accessories 10mm glass cuvette x 4, 10mm quartz cuvette x 2, Power cord, User’s Manual ,PC Analysis software
Double Beam UV Visible Spectrophotometer QTS-A44
Specifications:
Optical System Double Beam, Grating 1200 lines/mm
Wavelength Range 190-1100 nm
Spectral Bandwidth 0.5/1/2/4/5nm
Wavelength Accuracy ±0.1nm@656.1nm, ±0.3nm@all
Wavelength Repeatability <=0.1nm
Photometric Accuracy 0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A)
Photometric Repeatability ≤0.15%T (0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A)
Photometric Range 0-200%T, -0.3~3A, 0-9999C
Stray Light <=0.03%T@220nm, 360nm
Stability ±0.0005A/h@500nm
Baseline Flatness ±0.001A
Noise 0.0005A@500nm
Work Mode T, A, C, E
Scanning Speed Hi, Med, Low (Max. 3000nm/min)
Wavelength Setting Auto
Display 320*240 LCD
Light Source Deuterium & Tungsten lamp
Detector Imported Silicon Photodiode
Cuvette Holder 10mm manual 4-cell holder
Output USB, RS232
Power AC 110-220V 50-60Hz
Shipping Size 810*660*390mm
880*690*520mm Gross Weight 27kg
Standard Accessories 10mm glass cuvette x 4, 10mm quartz cuvette x 2, Power cord, User’s Manual ,PC Analysis software
Quantix Equipment is a rapidly growing leader in innovation and quality, specializing in the development and supply of advanced pharmaceutical testing equipment and support services.