pH
Ion
Conductivity
DO
| Model | QXP-FM80 | |
| Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal./DO Saturation) | |
| pH | Range | -2.000 to 20.000 pH |
| Resolution | 0.1, 0.01, 0.001pH | |
| Accuracy | ±0.002 pH | |
| Calibration Points | Up to 6 | |
| Standard Customization | Yes | |
| Calibration Reminder | Yes | |
| Standard Recognition | NIST, GB, DIN, USA, MERK, JIS buffers | |
| Slope Limit | Yes | |
| mV/ORP | Range | -2000.00 to 2000.00 mV |
| Resolution | 0.1, 0.01 mV | |
| Accuracy | ±0.1 mV or ±0.03% of
reading whichever is greater |
|
| EH ORP Mode | Yes | |
| ORP Calibration Points | 1 custom point (relative mV) | |
| pX | Range | -2.000 to 20.000 pX |
| Resolution | 0.1, 0.01, 0.001 pX | |
| Accuracy | ±0.002 pX | |
| Calibration Points | Up to 6 | |
| ISE | Range | 1E-9 to 9.999E9 |
| Units | mol/L, mmol/L, g/L, mg/L, μg/L, ppm | |
| Resolution | Up to 4 significant digits | |
| Accuracy | ±0.3% | |
| Calibration Points | Up to 6 | |
| Conductivity | Range | 0.000 μS/cm to 2000 mS/cm |
| Resolution | 0.001 μS/cm minimum,
various with range selection |
|
| Accuracy | ±0.5% FS | |
| Reference Temperature | 5, 10, 15, 18, 20, 25 ºC | |
| Calibration Points | Up to 5 | |
| Calibration Reminder | Yes | |
| Standard Recognition | 10 μS/cm, 84 μS/cm, 500 μS/cm, 1413 μS/cm, 12.88 mS/cm | |
| Resistivity | Range | 5.00 Ω·cm~100.00 MΩ·cm |
| Resolution | 0.01 Ω·cm minimum | |
| Accuracy | ±0.5% FS | |
| TDS | Range | 0.000~1000 ppt |
| Resolution | 0.001 ppm minimum, changed with range | |
| Accuracy | ±0.5%FS | |
| Salinity | Type | NaCl |
| Range | 0.0~80.0ppt | |
| Resolution | 0.1ppt | |
| Accuracy | ±1ppt | |
| Dissolved
Oxygen Concentration – Polarographic |
Range | 0.00 to 99.99 ppm |
| Resolution | 0.01 ppm | |
| Accuracy | 0.10ppm, 0.00~50.00ppm
±0.50ppm, 50.0~99.99ppm |
|
| Calibration Reminder | Yes | |
| Calibration Points | Air-saturated water or zero point | |
| Barometric Compensation | Yes | |
| Manual Salinity Factor Correction | Yes | |
| % Saturation -Polarographic | Range | (0.0 to 600)% |
| Resolution | 0.10% | |
| Accuracy | ±2.0% | |
| Temperature | Range | -10 to 135 ºC, 14 to 275 ºF |
| Unit | ºC, ºF | |
| Resolution | 0.1 | |
| Accuracy | ±0.1 | |
| Measurement | Reading Mode | Auto Read (Fast, Medium, Slow), Timed, Continuous |
| Reading Prompts | Reading, Stable, Locked | |
| Temp. Compensation | ATC, MTC | |
| Data management | Data Storage | 1000 Groups |
| GLP Features | Yes | |
| Log Management | Yes | |
| Inputs | pH Electrode | BNC(Q9) |
| DO with Temp. Probe | 4-pin aviation connector | |
| Conductivity with Temp. Probe | 5-pin aviation connector | |
| Outputs | USB | USB 2.0 flash memory device, PC |
| RS 232 | printer, scanner, auto-sampler | |
| Display options | Backlight | Yes |
| Auto Shutdown | 1~60 min, off | |
| IP Rating | IP54 | |
| Date and Time | Yes | |
| General | Electricity | AC Adapter, 100-240V AC input, DC24V output |
| Dimensions | 220×195×68 mm | |
| Weight | 950g | |