| ECG | Lead Mode: 5 Leads ( R, L, F, N, C or RA, LA, LL, RL,V) |
| Lead selection: I, II, III, avR, avL, avF, V, | |
| Waveform: 2 ch | |
| Lead mode: 3 Leads ( R, L, F or RA, LA, LL) | |
| Lead selection: I, II, III, | |
| Waveform: 1 ch | |
| Gain: ′2.5mm/mV, ′5.0mm/mV, ′10mm/mV, ′20mm/mV, auto | |
| HR and Alarm | |
| Range Adult: 15 ~ 300 bpm | |
| Neo/Ped: 15 ~ 350 bpm | |
| Accuracy : ± 1% or ± 1bpm,which great | |
| Resolution: 1 bpm | |
| Sensitivity: > 200 (uV P-P) | |
| Differential Input Impedance: > 5 MΩ | |
| CMRR | Monitor: > 105 dB |
| Operation: > 105 dB | |
| Diagnosis: > 85 dB | |
| Electrode offset potential: ±300mV | |
| Leakage Current: < 10 uA | |
| Baseline Recovery: < 3 S After Defi. | |
| ECG Signal Range: ±8 m V ( Vp-p ) | |
| Bandwidth | |
| Surgery: 1 ~ 15 Hz | |
| Monitor: 0.5 ~ 35 Hz | |
| Diagnostic: 0.05 ~ 100 Hz | |
| Calibration Signal: 1 (mV p-p), Accuracy:±5% | |
| ST Segment Monitoring Range: Measure and Alarm -2.0 ~ +2.0 mV | |
| ARR Detecting | |
| Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, | |
| TACHY, BRADY, MISSED BEATS, PNP, PNC | |
| Alarm: Available | |
| Review: Available | |
| RESP | Method: Impedance between R-F(RA-LL) |
| Differential Input Impedance: >2.5 MΩ | |
| Measuring Impedance Range: 0.3~5.0Ω | |
| Base line Impedance Range: 0 – 2.5 KΩ | |
| Bandwidth: 0.3 ~ 2.5 Hz | |
| Resp. Rate | Measuring and Alarm Range |
| Adult: 0 ~ 120 rpm | |
| Neo/Ped: 0 ~ 150 rpm | |
| Resolution: 1 rpm | |
| Accuracy : ±2 rpm | |
| Apean Alarm: 10 ~ 40 S | |
| NIBP | Method: Oscillometric |
| Mode: Manual, Auto, STAT | |
| Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min) | |
| Measuring Period in STAT Mode: 5 Min | |
| Pulse Rate Range: 40 ~ 240 bpm | |
| Alarm Type: SYS, DIA, MEAN | |
| Measuring and alarm range | |
| Adult Mode | |
| SYS: 40 ~ 270 mmHg | |
| DIA: 10 ~ 215 mmHg | |
| MEAN: 20 ~ 235 mmHg | |
| Pediatric Mode | |
| SYS: 40 ~ 200 mmHg | |
| DIA: 10 ~ 150 mmHg | |
| MEAN:20 ~ 165 mmHg | |
| Neonatal Mode | |
| SYS: 40 ~ 135 mmHg | |
| DIA:10 ~ 100 mmHg | |
| MEAN:20 ~ 110 mmHg | |
| Resolution Pressure:1mmHg | |
| Accuracy Pressure Maximum Mean error: ±5mmHg | |
| Maximum Standard deviation: ±8mmHg | |
| Overpressure Protection | |
| Adult Mode: 297±3 mmHg | |
| Pediatric Mode: 240±3 mmHg | |
| Neonatal Mode: 147±3 mmHg | |
| SpO2 | Measuring Range: 0 ~ 100 % |
| Alarm Range: 0 ~ 100 % | |
| Resolution: 1 % | |
| Accuracy : 70% ~ 100% ±2 % | |
| 0% ~ 69% unspecified | |
| Actualization interval: about 1 Sec. | |
| Alarm Delay: 10 Sec. | |
| Pulse Rate | |
| Measuring and Alarm Range: 20~300bpm | |
| Resolution: 1bpm | |
| Accuracy : ±2bpm | |
| TEMPERATURE | |
| Channel: 2 | |
| Measuring and Alarm Range: 0 ~ 50 °C | |
| Resolution: 0.1°C | |
| Accuracy : ±0.1°C | |
| Average Time Constant:<10 Sec. | |
| IBP | Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 |
| ART: 0 ~ 300 mmHg | |
| PA: -6 ~ 120 mmHg | |
| CVP/RAP/LAP/ICP: -10 ~ 40 mmHg | |
| P1/P2: -10 ~ 300 mmHg | |
| Press Sensor | |
| Sensitivity: 5 uV/V/mmHg | |
| Impedance: 300-3000Ω | |
| Resolution: 1 mmHg | |
| Accuracy : ±2% or ±1mmHg, which great | |
| Actualization interval: about 1 Sec | |
| Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature | |
| Optional: Nellcor SpO2, EtCO2,IBP, Touch screen, Thermal Recorder,Wall mount, Trolley, Central station,VGA |